    High Precision ±0.003 ° C Temperature Transmitter Calibration

    Ask Lasest Price
    Brand Name : PANRAN
    Model Number : PR231A-2
    Certification : CE,ISO9001
    Price : negotiable
    Payment Terms : TT, LC, Visa, Western Union, Alipay, Trade assurance, E-checking
    Supply Ability : 20 pcs / month
    Delivery Time : 15~25 working days
    • Product Details
    • Company Profile

    High Precision ±0.003 ° C Temperature Transmitter Calibration

    Displays Input And Output Simultaneously Of Thermometer Calibrator

    PANRAN Temperature Calibrators simulate process sensors for testing temperature instrumentation.

    Specifically designed for the field, these lightweight compact tools are EMI tolerant, dust and splash resistant and offer an easy to use single push button interface. When paired with a temperature sensor they can take high accuracy temperature measurements to verify process temperatures and ensure the highest product quality and safety. There are a variety of different temperature calibrators designed for your unique calibration and testing requirements.

    PANRAN offers a wide range of temperature calibration equipment. Everything from simple Stik Thermometers to temperature simulation/measurement calibrators to dry-blocks, micro-baths and metrology wells. Whether you’re looking to calibrate a temperature transmitter in the field, test an RTD sensor, simulate a thermocouple, or calibrate a temperature transmitter at the bench, PANRAN has a temperature calibrator for you.


    • Products Features




    Powerful, easy-to-use, high-accuracy temperature calibrator
    Test and calibrate temperature sensors and transmitters
    Measures 4 to 20 mA loops and can provide loop power
    Measures RTDs, thermocouples, ohms, and volts
    Source/simulates thermocouples, RTDs, volts, and ohms


    Precision temperature control function

    Using the precision temperature control function, temperature closed-loop control of the constant temperature equipment can be realized instead of the high-precision PID controller. In the case that the constant temperature equipment and grid voltage are satisfactory to the conditions, the temperature fluctuation of the equipment can be better than 0.02°C /10min (thermostatic bath).


    ρvalue measurement

    The PR231 series calibrator can measure the duty factor of the periodic square signal and can be used to verify and calibrate the PID parameters of various digital temperature indicating regulators for time proportional output, and meet the requirements of JJG 617-1996 Verification Regulation of Digital Temperature Indicators and Controllers.


    thermal calculator

    It is used to achieve various conversions between electric and temperature. The conversion support a variety of TCs, RTDs and thermistors.


    Value Settings

    The PR231 series calibrator has the most flexible and convenient output value setting method. It is possible to directly set the output value through the numeric keypad, or to increase the increment setting by pressing the direction key. In addition, the device has an editable phase step or slope value setting method.


    Sinusoidal signal output function

    The verification/calibration of some process loggers, especially mechanical recorders, usually involves the operation test. In this case, the user can use the device's sinusoidal signal output function to provide signals for the verified instrument.



    The verification/calibration of some process recorders (especially mechanical recorders) usually involves the operation of the test. At this time, the device's sinusoidal signal output function can be used to signal the meter.


    Data logging function

    The logging function saves measurement and output data. PR231 series calibrator has powerful record management functions. Up to 32 device numbers can be created. Each device number has 16 logging pages. Each logging page contains four kinds of basic information, namely time, measured value, output value and custom value. Basic information. Users can perform device processing, record deletion, etc. according to their needs.


    • PR231 series model selection table

    ItemPR231A-1PR231A-2PR231B-1PR231B-2
    Enhancement model
    Basic model
    0.01 grade
    0.02 grade

    • Basic Parameters

    Weight990gcharging source100~240V AC,50~60Hz
    Dimension225mm*130mm*53mmWorking temperature-10℃~50℃
    Cell type7.4V 4400mAh, Rechargeable lithium batteryWorking time≥20 hours(24V power off)
    Preheating time10 minutes after preheatingHumidity0~80%,Non condensing
    Charging time5 hoursCalibration period2 years

    • Performance Index

    1. Basic parameters of measurement:

    FunctionRangeMeasurement rangeResolution0.01 accuracy0.02 accuracyRemarks
    Voltage100mV-5mV~120mV0.1uV0.005%RD+5uV

    0.015%RD+

    5uV

    Input impedance

    ≥80mΩ

    1V-50mV~1.2V1uV

    0.005%RD+

    0.005%FS

    0.015%RD+

    0.005%FS

    10V-0.5V~12V10uV

    Input impedance

    ≥1mΩ

    50V-0.5V~50V0.1mV
    Current50mA-5mA~50 mA0.1uA0.005%RD+0.005%FS

    0.015%RD+

    0.005%FS

    Internal resistance =10Ω
    Ohm50Ω0Ω~50Ω0.1mΩ0.005%RD+5mΩ

    0.015%RD+

    5mΩ

    Output 1mA current
    500Ω0Ω~500Ω1mΩ0.005%RD+0.005%FS

    0.015%RD+

    0.005%FS

    5kΩ0kΩ~5kΩ10mΩOutput 0.1mA current
    Thermal coupleS,R,B,K,N,J,E,T,EA2,Wre3-25,Wre5-260.1℃/According to ITS-90 scale
    Cold end compensationInternal-10℃~60℃0.01℃0.5℃0.5℃
    External0.1℃0.1℃

    Thermal

    resistance

    Pt10,Pt100, Pt200,Cu50,Cu100,BA1,BA2,JPt100, Pt500, Pt10000.01℃/
    Standard temperatureS,R,B,T,SPt25,SPt1000.01℃/Need to enter the correction value
    ρ-value50S0.001%~99.999%0.001%0.005%0.005%Input pulse width amplitude range:1V~50V
    Frequency10Hz0.001Hz~12Hz0.001Hz0.01%FS0.01%FS
    1kHz

    0.00001kHz~

    1.2 kHz

    0.01Hz
    100kHz

    0.01kHz~

    120 kHz

    10Hz0.1%FS0.1%FS
    Temperature differenceS,R,B,K,N,J,E,T0.01℃/Need to enter the correction value
    SPt25,SPt1000.001℃

    2. Basic parameters of the output function:

    FunctionRange

    Measurement

    range

    Resolution0.01 accuracy0.02 accuracyRemarks
    Voltage100mV-20mV~120mV1uV0.005%RD+5uV0.015%RD+5uVMaximum load current =2.5mA
    1V-0.2mV~1.2V10uV0.005%RD+0.005%FS0.015%RD+0.005%FS
    10V-2V~12V0.1mV
    Current30mA-5mA~30 mA1uA0.005%RD+0.005%FS0.015%RD+0.005%FSMaximum load voltage =24V
    Ohm50Ω0Ω~50Ω0.1mΩ/According to ITS-90 scale
    500Ω0Ω~500Ω1mΩ
    5kΩ0kΩ~5kΩ10mΩ
    Thermal coupleS,R,B,K,N,J,E,T,EA2,Wre3-25,Wre5-260.1℃/

    Thermal

    resistance

    Pt10,Pt100, Pt200,Cu50,Cu100,BA1,BA2,JPt100, Pt500, Pt10000.01℃/

    Frequency

    / Pulse

    10Hz

    0.001Hz~

    12 Hz

    0.001Hz0.01%FS0.01%FSMaximum load current =2.5mA
    1kHz

    0.00001kHz~

    1.2 kHz


    0.01Hz

    100kHz0.01kHz~120 kHz10Hz0.1%FS0.1%FS
    Precision temperature controlS,R,B,K,N,J,E,T0.01℃/
    Pt100
    24V output

    Maximum voltage error: 0.3V Ripple noise:35mVp-p(20MHz bandwidth)

    Maximum load current:70mA Load regulation: 0.5%(10% -100% load change)


    • DETAILS INTRODUCE


    1. Measuring function terminal area (withstand 100V DC voltage input error)

    2. Output function terminal area(withstand 36V DC voltage input error)

    3. Dust cover

    4. Side band(length adjustable )

    5. Holder

    6. External Pt100 Reference point sensor interface

    7. USB2.0 communication interface

    8. Multi-function port (With RS232 communication, USB communication, isolated 24V voltage output, precision temperature control signal output, pressure calibration, and other functions)

    9. Reset

    10. Supply hub(Connect the external AC power adapter)

    11. Equipment nameplate

    12. Battery

    13.Protective tube

    14.Screen contrast adjusting knob

    15.Battery port


    a.Adjust length here

    b.Unfold jacket toward this direction

    c. Holder unfold direction